Commissioning & start-up
New units and the start-up after a gas generator exchange, including mapping on the LM6000 PF.
Telic Engineering / Engines / LM6000
Commissioning, annual and L1 inspections, start-up after a gas generator exchange, control upgrades and mapping on the LM6000. Power plants onshore and power generation on FPSOs, on Woodward MicroNet.
The six places on the LM6000 where most of our work happens, numbered as in the drawing at the top of the page.
By engineers who have done it before. Every job comes with a short daily report and paperwork you can use.
New units and the start-up after a gas generator exchange, including mapping on the LM6000 PF.
The controls and instrumentation scope of annual, semi-annual and L1 inspections, on FPSOs and onshore. Calibration sheets and a service report before we leave.
Your inspection crew, our engineer on the controls and instrumentation side: supervising, testing and signing off.
NetCon to MicroNet Plus migrations, HMI replacement and the commissioning that goes with it.
Trips, failed starts, fuel valve faults, temperature spread. We read the datalogs first and find the cause.
On multi-unit projects: an engineer who knows the control system inside out, next to the installation contractor.
What we have actually worked on. If your LM6000 package is not on it, ask.
Taken from our track record, newest first. No client or site names here; ask and we tell you, under NDA if needed.
| Period | Work | Equipment | Systems | Location |
|---|---|---|---|---|
| Feb–Mar 2026 | Annual inspections, functional checks | 2× gas turbines | LM6000, MicroNet | Offshore UK, FPSO |
| Jan–Feb 2026 | Annual inspections, functional checks | 2× gas turbines | LM6000, MicroNet | Offshore UK, FPSO |
| Nov 2025 | Commissioning, start-up, mapping | 1× gas turbine | LM6000 PF, MicroNet | UK |
| May 2024 | Supervising annual inspection, control and instrumentation | 1× gas turbine | LM6000, MicroNet | UK |
| Sep 2023 | L1 inspection, water wash commissioning, turning gear | 1× gas turbine | LM6000, MicroNet | UK |
| Aug–Sep 2023 | L1 inspection, instrumentation and control | 1× gas turbine | LM6000, MicroNet | Offshore UK, FPSO |
| May–Jun 2023 | L1 inspection, instrumentation and control | 1× gas turbine | LM6000, MicroNet | Offshore UK, FPSO |
| Aug 2022 | Semi-annual inspection, fuel valve replacement | 1× gas turbine | LM6000, MicroNet | Offshore UK |
| Jul–Aug 2021 | Commissioning, start-up after GG exchange | 1× gas turbine | LM6000, MicroNet | Offshore UK, FPSO |
| Oct 2020 | Borescope inspection | 1× gas turbine | LM6000 PF | UK |
| Period | Work | Equipment | Systems | Location |
|---|---|---|---|---|
| Mar 2018 | Control upgrade | 1× gas turbine | LM6000 PD, MicroNet | USA |
| Apr–May 2016 | Commissioning, control TA | Gas turbines | LM6000, MicroNet | Egypt |
| May–Jun 2015 | Commissioning, control TA | 12× gas turbines | LM6000, TM2500, MicroNet | Egypt |
| Nov–Dec 2012 | Commissioning support | 2× gas turbines | LM6000 | Italy |
Both. Much of our LM6000 work is for OEMs, packagers and service providers, as their field engineer. We also work directly for operators and owners. Where an OEM service contract is in place, we work alongside the OEM team, not around it.
Both. We are experts on Woodward and GE control systems. Most LM6000 packages we work on run Woodward MicroNet or MicroNet Plus; GE Mark VI and Mark VIe are just as familiar.
Hard-to-find and obsolete control and instrumentation parts for LM6000 packages, sourced through our supplier network, checked for compatibility, installed and tested on site.
Send the start date, location and scope and you get availability and an estimate the same working day. Offshore certificates (OPITO BOSIET/FOET, MIST, offshore medical) are kept current, so paperwork is not what holds you up.
Yes. For campaigns or several units at once we add contractors from our own network, under our agreement, our insurance and our reporting. How resource supply works.
Send the start date, estimated duration, scope, systems on site and location. You get availability and an estimate the same working day.
Request availabilityQuestion from purchasing or compliance? Company details, insurance, HSE and quality policies and procedures are on the Working with Telic page.